Von Duprin 99EO-F rim fire exit device, exit only, fire rated

Exit door & panic hardware checklist · Atlanta & North Metro, GA

Panic hardware requirements and an exit door checklist for Atlanta buildings.

On every exit door we repair, we check that the latch catches, the bar releases with one push, and the strike, rods and closer sit in line. Panic bar repair starts at $145. Below are that checklist and Section 1010.1.10 of the 2018 International Building Code, which says when an exit door needs panic hardware, in plain words.

IBC 2018 Section 1010.1.10 Panic bar repair from $145 Insured · certified locksmith
InsuredOn every job
24/7Emergency service, every day
FreeEstimate on site, before any work
34Towns from Douglasville to Dawsonville

What the code text says

Exit door hardware requirements, from the code text.

Quoted or closely paraphrased from the 2018 International Building Code, Chapter 10. The local fire marshal may also apply the NFPA 101 Life Safety Code, and the fire marshal or building official has the final word on any door, so ask them before you change one.

Which doors: IBC 2018 Section 1010.1.10

Swinging doors serving a Group H occupancy, and swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy, "shall not be provided with a latch or lock other than panic hardware or fire exit hardware." The building official decides a building's occupancy group and occupant load.

The two exceptions in Section 1010.1.10

A main exit of a Group A occupancy may have locking devices in accordance with Section 1010.1.9.4, Item 2. Doors with panic or fire exit hardware serving a Group A or E occupancy may be electrically locked in accordance with Section 1010.1.9.9 or 1010.1.9.10.

Electrical rooms: Section 1010.1.10

Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet wide, that contain overcurrent, switching or control devices with exit or exit access doors, shall be equipped with panic hardware or fire exit hardware, and the doors shall swing in the direction of egress travel.

Installation: Section 1010.1.10.1

Where panic or fire exit hardware is installed, panic hardware shall be listed in accordance with UL 305, and fire exit hardware in accordance with UL 10C and UL 305. The actuating portion shall extend at least one-half of the door leaf width, and the maximum unlatching force shall not exceed 15 pounds.

Balanced doors: Section 1010.1.10.2

If balanced doors are used and panic hardware is required, it shall be the push-pad type, and the pad shall not extend more than one-half the width of the door measured from the latch side.

Door operations: Section 1010.1.9

Except as that section specifically permits, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Section 1010.1.9.2 sets operating hardware at 34 inches minimum and 48 inches maximum above the finished floor, with listed exceptions, and Section 1010.1.9.6 says unlatching any door or leaf shall not require more than one operation.

Related: Panic bar repair · Fire-rated door hardware · Von Duprin exit devices · Alarmed exit doors · Door closers

How we work

Our exit door hardware checklist.

Latching and dogging

We close the door several times and watch whether the latch catches the strike. Where the device has dogging, we check it holds the latch back and releases cleanly at closing time.

Corbin Russwin ED2200 rim exit device, hex key dogging

Strike, rods and closer

We check the strike is tight and in line, vertical rods are adjusted top and bottom, and the closer brings the door shut without slamming or stopping short.

Sargent 12-8910F mortise exit device, fire rated, for 33 to 36 inch doors

Trim, alarm and wear

We look at the outside trim and cylinder, any exit alarm on the device, and signs of wear: a loose bar, a cracked end cap, worn springs. Then you get the list and a price for anything that needs work.

Detex ECL-230D alarmed panic exit control lock

See the hardware we work on

Why businesses call us

The same checklist on every exit door.

We run this list on every exit door we repair, so a second fault on the same door is not missed.

  • Insured, certified locksmith
  • Exit door repairs at any hour, seven days
  • Common exit device parts on the van
  • Exit device prices listed below
  • We quote the code text, never guess at it
Detex V40 rim exit device, wide stile, delayed egress

How it is priced

How exit door work is priced.

Every price here is a starting price. We walk the exit door with the checklist at no charge and price each item before any work.

Always included

  • A free on-site estimate
  • Working through the checklist on the door
  • A list of what needs work, with prices

What changes the price

  • Rim, mortise or vertical-rod device
  • Repair parts or a new device
  • Outside trim, cylinder or exit alarm

Prices

Exit door hardware prices.

Starting prices. We confirm the final one at the door before any work.

The jobStarting at
Panic bar repair$145
Rim exit device, supplied and fitted$495
Vertical-rod exit device, supplied and fitted$895
Detex alarmed exit, service$95
Detex alarmed exit, installed$575
Door closer adjustment$125

Who we work for

Who this checklist is for.

RestaurantsChurchesSchools and daycaresOfficesWarehousesProperty managersFacility companies

Questions we get

Panic hardware questions.

Something not covered here? Call or text (470) 375-0631 and ask the locksmith directly.

When do I need panic hardware?

IBC 2018 Section 1010.1.10 covers swinging doors serving Group H occupancies, and doors serving rooms or spaces with 50 or more occupants in Group A or E occupancies: if they latch or lock, it must be panic or fire exit hardware. Your building official or fire marshal confirms whether your door is one of them.

How hard should a panic bar be to push?

Section 1010.1.10.1 sets the maximum unlatching force at 15 pounds. A bar that needs more usually has a dragging door, a worn mechanism or a strike out of line, and we can repair it.

How wide does the push bar have to be?

Section 1010.1.10.1 says the actuating portion shall extend not less than one-half of the door leaf width.

Who decides whether my exit door passes?

The local fire marshal or building official. We repair and install the hardware; they have the final word on what the code requires for your building.

Where we work

Exit door and panic hardware service across north metro Atlanta.

We come to you: on-site service across the communities below.

AtlantaSandy SpringsDunwoodyBrookhavenChambleeDoravilleDecaturTuckerStone MountainSmyrnaMabletonAustellDouglasvilleMariettaKennesawAcworthWoodstockCantonRoswellAlpharettaMiltonJohns CreekPeachtree CornersNorcrossDuluthLilburnSnellvilleLoganvilleLawrencevilleDaculaSuwaneeBufordCummingDawsonville

Building just outside these towns? Call or text anyway, and we will tell you straight whether we can reach it.

Page updated November 2026

Free estimate on site

Exit door not latching, or a device to replace?

A locksmith calls you back to confirm the door, the hardware and the starting price before anyone drives out.

(470) 375-0631Call or text
We come to youOn-site service, no walk-in shop
Get a quote Call now